Ultrasound-guided biopsy

Dr Bruno Di Muzio and Dr Ian Bickle et al.

Ultrasound-guided biopsy is one form of image-guided biopsy, typically performed by a radiologist. It is the most common form of image-guided biopsy, offering convenience and real-time dynamic observation with echogenic markers on cannulae allowing for precise placement.

It can potentially be used to perform a biopsy of any body part, being regularly used to biopsy the kidney, liver, breast and lymph nodes. There can be some minor procedural variation in the type of biopsy performed.

Biopsies may be focal or non-focal in nature. Lesions as small as 5 mm may be biopsied, with a range of biopsy needle gauges and sizes available (from 22G to 14G). Broadly speaking needles may be single or co-axial and have 10 mm or 20 mm cutting lengths.

Most common percutaneous biopsies
Laboratory parameters for a safe procedure

Biopsies in deep structures require special attention to coagulation indices. There are widely divergent opinions about the safe values of these indices for percutaneous biopsies. The values suggested below were considered based on the literature review, whose references are cited below.

Complete blood count: Platelet > 50000/mm3  (some institutions determine other values between 50000-100000/mm31,3.

Coagulation profile: Some studies showed that having a normal INR or prothrombin time is no reassurance that the patient will not bleed after the procedure2.

  • international normalized ratio (INR) ≤1.5 3
  • normal prothrombin time (PT), partial thromboplastin time (PTT)
Contraindications

The contraindications must be considered individually in each case. Overall, the most important contraindications to percutaneous biopsies are:

  • uncooperative patient
  • lack of safe access
  • uncorrectable bleeding diathesis (abnormal coagulation indices)
Ultrasound - general index
Interventional procedures
Share article

Article information

rID: 21143
Tag: refs
Synonyms or Alternate Spellings:
  • Ultrasound guided biopsies

Support Radiopaedia and see fewer ads

Cases and figures

  • Figure 1: photograph - typical co-axial needle
    Drag here to reorder.
  • Case 1: breast mass
    Drag here to reorder.
  • Figure 2: photograph - renal biopsy gun
    Drag here to reorder.
  • Case 2: needle position beautifully illustrated
    Drag here to reorder.
  • Case 3: liver biopsy
    Drag here to reorder.
  • Case 4: hemorrhage post liver biopsy
    Drag here to reorder.
  • Case 5
    Drag here to reorder.
  • Case 6: head and neck biopsy
    Drag here to reorder.
  • Case 7: neck node
    Drag here to reorder.
  • Case 8: lung
    Drag here to reorder.
  • Updating… Please wait.

     Unable to process the form. Check for errors and try again.

     Thank you for updating your details.